Electrolyzer Preparation – Quick Review Notes
ABS Plate Setting
- Use AKC torque-limited screwdriver (set to 3\,\text{N·m}); prevents cracking.
- Temporary fix 1 m ABS plates ➔ level adjustment:
• Measure 5 points/side; left-right deviation < 2.0mm
• North-side deviation < 1.0mm (use piano wire)
• Plate spacing = 2670±1.5mm - Eliminate steps at joints (straight edge + emery paper).
- Fill screw holes & gaps ≥1mm with 1:1 epoxy; tape edges, cure, smooth; silicone sealant acceptable substitute.
- Final step: grease top surface for smooth cell-frame travel.
Insulation & Terminal Cell Frames
- PP insulation plates t=10mm
• Single press: 2 plates • Double press: 4 plates - Center plates evenly; handle gently.
- Hoist terminal frames individually (weights: anode 558kg, cathode 581kg); keep area clear.
- Align guide notch to ABS plates using lever jig; secure 4 points (loose-head: connecting bars; fast-head: turnbuckles).
Bipolar & PDT Frames
- Hoist up to 12 bipolar frames at once (each 189kg); avoid shaking/hits.
- Insert PVC spacers between frames (2 spacers for each terminal frame).
- Install PDT frame at 25th position from anode (A001-B024-Z001 order).
Tank & Piping Cleaning
- After construction: flush with water; bypass electrolyzers.
- Fit #40 mesh screen on pump suction; inspect regularly.
- Post-circulation: clean tank interiors; monitor pump cavitation.
- Position per engineering docs; inlet S/H gradient = 1/200.
- Support S/H without obstructing nuts.
- Hose routing: anode inlet ➔ anode outlet; cathode inlet ➔ cathode outlet; plug unused inlets.
- Inlet hose: long leg toward cell frame; perform direction check at both ends & center of each half.
- Adjust outlet nozzles so hose sleeve contacts gasket flat.
LI Valve Unit
- Install before leak test.
- Hose: PVC, 12×10mm (PDT); height >3.1m; folded end must reach floor drain.
- Valves: anode = PVC (brown); cathode = PP (white).
- Expect brine/caustic splash—wear protection.
Cathode Wire Inspection & Repair
- PPE: thin rubber gloves (0.08mm), remove bulky gear.
- Gently stroke cathode surface; feel welded areas & anode edges.
- Inspection paths: (1) horizontal, (2) vertical, (3) edge.
- Protruding wire: lift with tweezers, cut with nippers, re-check; avoid mattress compression.
Key AKC Supplies (excerpt)
- Ion-exchange membrane, PP insulation plates, ABS plates, cell frames (terminal, bipolar, PDT), PVC/PP hoses, PVC spacers.
- Auxiliary electrodes, nickel plates, titanium caps, lever jig, #200 mesh for hydraulic flushing, epoxy adhesive, locking pins.