Principles and Purposes of Peripheral IV Therapy
- Intravenous (IV) therapy involves the administration of liquid substances directly into the vein for systemic distribution.
- Core therapeutic purposes of IV therapy include:
- Providing daily body fluid replacement when oral fluid ingestion is impossible or contraindicated.
- Replacing abnormal or excessive fluid or electrolyte losses.
- Providing a direct avenue for the continuous or intermittent parenteral administration of medications.
- Note: Providing pre-operative comfort to a patient is not a clinical purpose of IV therapy.
- Physiological rationale for maintaining fluid volume:
- Inadequate fluid volume within the cardiovascular system makes it impossible to maintain adequate perfusion and circulation to cells, tissues, and organs, which is required to sustain life.
IV Solutions and Osmolality

- Hypotonic IV Solutions:
- Defined as fluids having a lower concentration of dissolved solute particles compared to normal human body fluids.
- Causes fluid to shift out of the vascular space into the intracellular space.
- Isotonic IV Solutions:
- Defined as fluids having an equal concentration of dissolved solute particles compared to body fluids.
- Maintains fluid balance between intravascular and cellular spaces without causing cellular fluid shifts.
- Hypertonic IV Solutions:
- Defined as fluids having a higher concentration of dissolved solute particles compared to body fluids.
- Draws fluid out of the intracellular space and into the vascular space.
- Common IV Fluid Abbreviations and Labeling:
- D5W: 5% Dextrose Injection USP.
- D521NS: 5% Dextrose and 0.45% Sodium Chloride Injection USP.
- D5NS: 5% Dextrose and 0.9% Sodium Chloride Injection USP.
- NS: 0.9% Sodium Chloride Injection USP.
Equipment and Peripheral Vascular Access Devices


- Standard IV Start Kit Packaging Specifications:
- Reorder Code: IV6535R.
- Manufactured by Centurion Medical Products Corp. (Williamston, MI 48895 USA; Assembled and packaged in Mexico).
- Kit Contents:
- 1 Tourniquet
- 1 ChloraPrep® applicator (Chlorhexidine gluconate; sterile applicator)
- 1 Gauze sponge
- 3 Tape strips
- 1 VersaDerm® 2000 transparent dressing
- Storage and Safety Requirements: Store between 15–30∘C (59–86∘F). Latex Free. Ethylene Oxide (EO) sterilized. Single-use only. Do not use if package is open or damaged.
- Protocol hint: Remove only ONE tourniquet from ONE IV start kit during site preparation; keep the remaining components of the start kit intact within the sterile field.

- Universal Cannula Size Color-Coding Standard:
- 14 Gauge: Red (Large bore, high-volume trauma resuscitation)
- 16 Gauge: Gray (High-volume fluid/blood infusion)
- 18 Gauge: Green (Standard surgery, blood transfusions)
- 20 Gauge: Pink (Standard adult medical/surgical routine IV access)
- 22 Gauge: Blue (Older adults, pediatric patients, slow infusions)
- 24 Gauge: Yellow (Neonatal, pediatric, small fragile veins)

- Winged Infusion Sets (Butterfly Needles):
- Feature plastic wings on either side of the needle shaft to allow precise angle control during insertion into small or fragile surface veins.
- Utilize the same standardized gauge color-coding system.
Intermittent Infusions and Flush Protocol Safety


- Terminology:
- PRN Lock / Saline Lock (SL) / Heparin Lock: An intermittent vascular access device placed in a peripheral vein allowing scheduled or emergency IV medication access without requiring continuous intravenous fluid infusion.
- Primary Infusion Set: Standard main tubing used for continuous delivery of primary intravenous fluids.
- IV Piggyback (IVPB): Intermittent secondary medication infusion connected to a port on the primary line.
- IV Push (IVP): Direct slow manual injection of medication into an access port.
- Heparin Lock Flush Strengths & Lethal Error Warning:
- Standard strengths appropriate for flushing and maintaining patency of a PRN lock: 10USP units/mL or 100USP units/mL.
- High-Alert Safety Warning: Therapeutic anticoagulant dosages of Heparin Sodium Injection (e.g., 1,000USP units/mL or 5,000USP units/mL) must NEVER be used to flush a PRN lock.
- Flushing a catheter with therapeutic concentrations causes life-threatening systemic anticoagulation and severe internal hemorrhage.
- Always double-check medication labels against the Rights of Medication Administration prior to flushing access devices.
IV Flow Rate Calculations (Gravity and Infusion Pump)
- Infusion Time Calculation:
Infusion Time (hours)=Infusion Rate (mL/hr)Total Volume (mL)
- Example: Calculate total infusion time for 1000mL running at 125mL/hr:
Time=125mL/hr1000mL=8hours
- Gravity Infusion Flow Rate Calculations (Drops per Minute):
Flow Rate (gtt/min)=Time (min)Volume (mL)×Drop Factor (gtt/mL)
- Workbook Example 1 (Problem #50):
- Order: Infuse 100mL/hr. Drop factor: 12gtt/mL.
Rate=60min100mL×12gtt/mL=601200=20gtt/min
- Workbook Example 2 (Problem #51):
- Order: Infuse 75mL/hr. Drop factor: 10gtt/mL.
Rate=60min75mL×10gtt/mL=12.5≈13gtt/min
- Workbook Example 3 (Problem #52):
- Order: Infuse 125mL/hr. Drop factor: 20gtt/mL.
Rate=60min125mL×20gtt/mL=602500=41.66≈42gtt/min
- Electronic Infusion Pump Calculations (mL per Hour):
- Infusion pumps are programmed exclusively in mL/hr; drop factor calculations are unnecessary.
- Standard Equation:
Pump Rate (mL/hr)=Time (min)Volume (mL)×60min/hr
- Example 1 (Gentamycin): Gentamycin 80mg in 100mL D5W over 30minutes:
Pump Rate=30min100mL×60min/hr=200mL/hr
- Example 2 (Unasyn): Unasyn 500mg in 50mL D5W over 15minutes:
Pump Rate=15min50mL×60min/hr=200mL/hr
- Example 3 (Continuous Line): Infuse 1000mL over 10hours:
Pump Rate=10hours1000mL=100mL/hr
Pre-Initiation Assessment and Site Selection
- Required Assessments Prior to IV Initiation:
- Verify medical order and specific indication/purpose for IV access.
- Review medical history and chart notes.
- Screen for allergies to tape, latex, or iodine/chlorhexidine antiseptics.
- Vein Dilation Techniques:
- Apply a moist warm pack over the intended extremity for 10–15minutes.
- Position the extremity dependent (below heart level) to encourage blood pooling.
- Contraindicated Practices: Avoid firmly tapping skin over veins (causes arterial spasm/venous constriction), avoid elevating the extremity on pillows (drains venous volume), and avoid overtightening tourniquets (restricts arterial inflow).
- Sites and Extremities to Avoid:
- Extremities on the side of a prior mastectomy (risk of worsening lymphedema).
- Paralyzed limbs (impaired venous return and altered sensation).
- Extremities containing an active arteriovenous (AV) shunt or dialysis fistula.
- Veins extending across a flexible joint (e.g., wrist, antecubital fossa) due to mechanical irritation and displacement.
- Veins smaller than the catheter gauge.
- Veins with a visible bump or bifurcation, which indicates the presence of a venous valve.
- Dorsal aspect of the hand in older adult patients due to skin fragility and hyper-mobile, easily bruised vessels.
Venipuncture Technique and Troubleshooting

- Troubleshooting Unsuccessful Insertion:
- If initial venipuncture produces no blood return into the flashback chamber, remove the needle and catheter assembly completely.
- Attempt subsequent venipunctures in a more proximal vein (higher up on the arm) or on the opposite arm.
- Safety Protocol: Never reinsert the metal stylet/needle into the catheter cannula while inside the body or attempt to re-thread a retracted needle, as this risks shearing the tip and causing a catheter embolism.
- Restarting an Infiltrated IV:
- Once an IV infiltrates, select a vein proximal to the damaged site or choose an alternative vein on the opposite arm.
- Never select a vein distal to an infiltrated site on the same vein/arm because infused solution will extravasate out of the damaged puncture site upstream.
- Forearm veins provide the most stable sites for re-starting IV access.
IV Therapy Complications and Pump Alarms
- Complications of IV Therapy:
- Infiltration (fluid leaking into surrounding tissue).
- Extravasation (tissue necrosis from vesicant leakage).
- Septicemia (systemic bloodstream infection).
- Circulatory fluid overload.
- Phlebitis (venous wall inflammation).
- Air Embolism & Catheter Embolism.
- Speed Shock (systemic reaction from excessively rapid drug administration).
- Note: Discomfort at the time of initial skin insertion is an expected procedural sensation, not a clinical complication.
- Electronic IV Infusion Pump Safety:
- Pumps contain alarms that automatically trigger for:
- IV line occlusion/increased line pressure.
- Empty fluid bag/container.
- Air detected in the infusion line.
- System operational errors or low battery.
- Critical Limitation: Infusion pumps cannot detect human entry errors (e.g., if a nurse incorrectly programs the rate into the device interface).
Special Population Considerations (Pediatrics and Older Adults)
- Pediatric Patients and High-Risk Populations:
- Conduct IV site, rate, and safety assessments every 1hour in children, older adults, and clients prone to fluid overload.
- Always use microdrip tubing (60gtt/mL) for pediatric clients to prevent accidental fluid volume boluses.
- Older Adult Considerations:
- Avoid tourniquet use whenever possible due to skin and vein fragility; substitute a blood pressure cuff inflated slightly below diastolic pressure.
- Avoid excessive skin friction or prolonged tapping during site preparation.
- Select non-irritating, low-tack tapes and remove dressings with extreme care to prevent skin tears.
Blood Product Administration Guidelines
- Required Solution Compatibility:
- 0.9% Normal Saline (0.9% NaCl) is the ONLY intravenous solution authorized for priming lines, co-infusing, and flushing tubing before and after blood product transfusions.
- Incompatible Solutions: Dextrose solutions cause red blood cell hemolysis (clumping/cell destruction); hypotonic solutions cause cellular swelling and lysis; hypertonic solutions cause red cell crenation.