Wk 10 - Bisecting Technique, Occlusal and Localization Techniques
Foundations and Terminology of the Bisecting Technique
The bisecting technique is an intraoral radiographic method used to expose periapical images based on geometric principles of plane geometry.
Key geometric and anatomical terminology:
Angle: A figure formed by two lines diverging from a common point.
Bisect: To divide into two equal parts.
Triangle: A figure formed by connecting three points not in a straight line by three straight-line segments; has three angles.
Equilateral Triangle: A triangle characterized by three equal sides and three equal interior angles.
Right Triangle: A triangle containing one right angle ().
Congruent Triangles: Triangles that are identical in shape and size, corresponding exactly when superimposed.
Hypotenuse: The side of a right triangle located directly opposite the right angle.
Isometry: Equality of measurement between geometric figures.
Long Axis of the Tooth: An imaginary line dividing the tooth longitudinally into two equal halves from incisal edge/occlusal surface to the root apex.
Central Ray: The central portion of the primary beam of x-radiation exhibiting the straightest, most perpendicular path of emission.
Historical and alternative nomenclatures for the bisecting technique:
Bisecting-angle technique
Bisecting-angle instrument (BAI) technique
Short-cone technique
Bisection-of-the-angle technique
Principles and Geometry of Bisecting (Rule of Isometry)
Rule of Isometry:
States that two triangles are equal if they have two equal angles and share a common side.
In dental radiography, this geometric theorem is applied to ensure that the radiographic image of the tooth possesses the exact anatomical length of the tooth being imaged.

Biomechanical and Geometric Implementation:
The receptor is placed along the lingual surface of the tooth.
The plane of the receptor and the long axis of the tooth intersect, forming an angle at the point where the receptor contacts the tooth.
The radiographer visualizes an imaginary bisector dividing the angle formed by the plane of the receptor and the long axis of the tooth into two equal halves.
The central ray of the x-ray beam is directed perpendicular () to the imaginary bisector.
When the central ray is directed at to the imaginary bisector, two imaginary right triangles result.
These resulting triangles are congruent, meaning the length of the tooth on the receptor equals the actual length of the tooth in the oral cavity.

Receptor Stabilization and Beam Alignment Devices
Receptors used in the bisecting technique can be stabilized using beam alignment devices or receptor holding instruments:
Beam Alignment Devices:
Mechanically position the intraoral receptor and provide external aiming rings.
Aiming rings align the position-indicating device (PID) with the tooth and receptor in both horizontal and vertical planes.
Strongly recommended because they eliminate the need for the patient to stabilize the receptor manually.
Example: Rinn BAI System.
Receptor Holding Devices:
Position the receptor intraorally and maintain stability during exposure without an external aiming ring.
Examples: Stabe bite-block (disposable styrofoam block) and Snap-A-Ray (formerly EEZEE-Grip holder).

Angulation of the Rinn BAI Instrument:
The receptor bite-block of the Rinn BAI is deliberately manufactured out of parallel alignment with the external metal guide arm and aiming ring.
This non-parallel design accounts for the angulation differential between the receptor and tooth, directing the PID automatically perpendicular to the imaginary bisector rather than the long axis of the tooth.

PID Angulation Principles: Horizontal and Vertical Planes
Angulation describes the alignment of the central ray of the x-ray beam relative to the horizontal and vertical planes.
Determining angulation is critical in bisecting when utilizing receptor holding devices that lack an aiming ring.
Horizontal Angulation:
Refers to the positioning of the tubehead and direction of the central ray in a side-to-side (horizontal) plane.
Correct Horizontal Angulation: The central ray is directed perpendicular to the curvature of the arch and straight through the contact areas of the teeth; the open face of the PID aligns parallel to the receptor face.
Incorrect Horizontal Angulation: Results in overlapping contact areas, obscuring interproximal surfaces and precluding diagnostic evaluation of proximal caries.


Vertical Angulation:
Refers to the positioning of the PID in an up-and-down (vertical) plane.
Calibrated in degrees on the exterior casing of the x-ray tubehead dial.
In the bisecting technique, vertical angulation is determined by directing the central ray perpendicular () to the imaginary bisector (contrasting with paralleling technique where the beam is directed perpendicular to both tooth long axis and receptor).
Correct Vertical Angulation: Generates a radiographic image exhibiting the true physical length of the tooth.
Incorrect Vertical Angulation: Generates dimensional image distortion (foreshortening or elongation).
Directional Orientation of Angulation:
Positive () Vertical Angulation: Tubehead is positioned above the occlusal plane with the PID pointing downward.
Negative () Vertical Angulation: Tubehead is positioned below the occlusal plane with the PID pointing upward.
Clinical Analogy: Positive vertical angulation mirrors "positive sun-rays coming down at us from above."

Vertical Angulation Errors: Foreshortening and Elongation
Foreshortening:
Manifestation: Radiographic images appear markedly shortened with compressed roots and crowns.
Etiology: Caused by excessive vertical angulation (PID is angled too steep).
Geometric mechanism: The central ray is directed perpendicular () to the plane of the receptor instead of the imaginary bisector.
Clinical mnemonic: Steep = Short.


Elongation:
Manifestation: Radiographic images appear stretched, exceedingly long, and distorted beyond actual anatomical dimensions.
Etiology: Caused by inadequate (insufficient / too flat) vertical angulation.
Geometric mechanism: The central ray is directed perpendicular () to the long axis of the tooth instead of the imaginary bisector.


Recommended Vertical Angulations for Periapical Projections
Standardized predetermined vertical angulation ranges utilized in bisecting periapical radiography when operating without alignment rings:
Anatomical Region | Maxillary Vertical Angulation | Mandibular Vertical Angulation |
|---|---|---|
Incisors | ||
Canines | ||
Premolars | ||
Molars |
Practical Laboratory Note: Predetermined clinical ranges differ from values programmed on dental simulator manikins (e.g., Dexter in RadLab).
Fundamental Rules and Procedural Steps of the Bisecting Technique
Five Cardinal Rules for Bisecting Technique:
Receptor Placement: The receptor must be positioned to cover the prescribed anatomical area of the teeth to be examined.
Receptor Position: The receptor must be positioned against the lingual surface of the tooth. The occlusal/incisal edge of the receptor must extend approximately beyond the incisal or occlusal surfaces.
Vertical Angulation: The central ray of the x-ray beam must be directed perpendicular () to the imaginary bisector that divides the angle between the receptor and the long axis of the tooth.
Horizontal Angulation: The central ray of the x-ray beam must be directed through the interproximal contact spaces between the teeth.
Receptor Exposure: The x-ray beam must be centered over the receptor to ensure that all areas of the receptor are exposed; failure to center the beam results in cone-cut artifacts.

Step-by-Step Clinical Workflow:
Patient Preparation:
Explain all diagnostic imaging procedures clearly to the patient.
Adjust patient seating upright so the chair supports the spine comfortably.
Adjust the headrest: the patient's maxillary arch must be parallel to the floor, and the midsagittal (sagittal) plane must be perpendicular to the floor.
Place and securely fasten the protective lead apron equipped with a thyroid collar.
Request removal of eyeglasses and any intraoral appliances/objects (dentures, partials, retainers, oral piercings, chewing gum).
Equipment Preparation:
Regulate exposure factors (kilovoltage, milliamperage, time) according to patient size and receptor requirements.
Aseptically open sterilized packaging containing receptor holders and positioning devices in accordance with infection control protocol.
Exposure Sequencing:
Always commence exposures with anterior periapicals (better tolerated, minimal gag reflex activation).
Anterior sequence ():
Maxillary right canine
Maxillary central/lateral incisors
Maxillary left canine
Mandibular left canine
Mandibular central/lateral incisors
Mandibular right canine
Posterior sequence ( divided among four quadrants):
Maxillary right quadrant (premolars, then molars)
Mandibular right quadrant (premolars, then molars)
Maxillary left quadrant (premolars, then molars)
Mandibular left quadrant (premolars, then molars)
Receptor Spatial Orientation:
Anterior periapical projections: Receptors are positioned vertically.
Posterior periapical projections: Receptors are positioned horizontally.
Anterior bite-block tip: The corner edge of the receptor bite-block is centered in the biting position to ensure full incisal edge coverage.
Prescribed Anatomical Placements for Periapical Projections
Anterior Periapical Prescriptions (Box 20-1):
Maxillary Canine:
Entire crown and root of the canine, including apex and surrounding periodontium, must be clearly visible.
Interproximal alveolar bone and the mesial contact area of the canine must be documented.
Clinical Caveat: The lingual cusp of the maxillary first premolar usually superimposes over and obscures the distal contact of the canine.
Maxillary Incisor:
Entire crowns and roots of all four maxillary incisors (both centrals and laterals), including apices and periapical bone, must appear centered on the image.
Interproximal alveolar crests between central incisors and between central and lateral incisors must be visible.
Mandibular Canine:
Entire crown and root of the canine, including the root apex and supporting alveolar bone, must be captured.
Interproximal alveolar bone along with mesial and distal contact spaces must be open and unobstructed.
Mandibular Incisor:
Entire crowns and roots of all four mandibular incisors, including root apices and surrounding periodontium, must be present.
Contact spaces between both central incisors and between central and lateral incisors must be visible.
Posterior Periapical Prescriptions (Box 20-2):
Maxillary Premolar:
Crowns and roots of first and second premolars, first molar, including apices, alveolar crests, contact areas, and surrounding bone.
The distal contact area of the maxillary canine must be visible.
Maxillary Molar:
Crowns and roots of first, second, and third molars, including apices, alveolar crests, interproximal contacts, bone structures, and the maxillary tuberosity region.
The distal contact area of the maxillary second premolar must be visible.
Mandibular Premolar:
Crowns and roots of first and second premolars and first molar, including apices, alveolar crests, contact areas, and alveolar bone.
The distal contact area of the mandibular canine should be visible.
Mandibular Molar:
Crowns and roots of first, second, and third molars, including apices, alveolar crests, contact areas, and surrounding bone.
The distal contact area of the mandibular second premolar must be visible.
Clinical Advantages and Disadvantages of the Bisecting Technique
Advantages:
Can be executed without beam alignment devices when patient anatomy precludes their use (e.g., shallow palate, large palatal or mandibular tori, sensitive or shallow floor of the mouth).
Decreased exposure time when paired with a short () position-indicating device (due to inverse square law dynamics requiring less total radiation output compared to a PID).
Disadvantages:
Image Distortion: Non-parallel relationship between tooth long axis and receptor introduces inevitable dimensional magnification and distortion.
Angulation Complexities: Without alignment rings, the operator must independently estimate the imaginary bisector and assign vertical angulations, vastly increasing technical operator error.
Short PID Drawbacks: Increased x-ray beam divergence produces increased focal spot-to-object magnification.
Occlusal Examination Principles, Terminology, and Clinical Indications
Terminology:
Occlusal Surface: Chewing surfaces of posterior dentition.
Occlusal Examination: Intraoral radiographic inspection designed to view extensive sections of the maxilla or mandible on a single large-format image.
Occlusal Technique: Specialized exposure protocol where the patient bites down directly on the receptor surface.
Occlusal Receptor: Standard intraoral size 4 receptor used for adults; size 2 receptor utilized for pediatric patients.
General Purpose and Clinical Indications:
Used as a supplementary diagnostic imaging modality alongside standard periapical and bitewing series.
Preferred when clinical interest encompasses an area larger than a standard size 2 periapical receptor can record.
Preferred when intraoral placement of periapical holders is impossible due to extreme patient discomfort, physical trauma, or developmental stage.
Specific Diagnostic Applications:
Locate retained roots of extracted teeth.
Locate supernumerary, unerupted, or impacted dentition.
Locate foreign objects embedded in the maxilla or mandible.
Identify and evaluate sialoliths (salivary stones) within the submandibular (Wharton) duct.
Locate and delineate boundaries of cystic lesions, tumors, or osteomyelitis in the jaws.
Evaluate boundaries and expansion of the maxillary sinus.
Evaluate osseous fractures of the maxilla or mandible.
Aid in the radiological assessment of patients with severe trismus (cannot open mouth more than a few millimeters).
Examine skeletal defects in patients presenting with cleft palate.
Measure progression and changes in jaw size, lateral expansion, and arch shape.
Underlying Principles:
The receptor is placed horizontally into the mouth between the occlusal surfaces of the maxillary and mandibular arches.
The active white/tube side of the receptor faces the dental arch being investigated.
The patient stabilizes the receptor by gently biting down across its flat planar surface.
Maxillary and Mandibular Occlusal Projections: Techniques and Angulations
Patient Head Positioning Standards:
Maxillary Occlusal Projections: The patient's head is stabilized upright so the maxillary occlusal plane is parallel to the floor, and the midsagittal plane is perpendicular to the floor.
Mandibular Occlusal Projections: The patient is reclined back in the dental chair so that the mandibular occlusal plane is positioned perpendicular to the floor (especially for cross-sectional projections) or tilted back at a designated incline.
Maxillary Projections:
Maxillary Topographic Projection:
Clinical application: Evaluates the anterior hard palate and maxillary anterior teeth.
Vertical angulation: Central ray directed at through the bridge of the nose.


Maxillary Lateral Projection (Right or Left):
Clinical application: Evaluates palatal roots of maxillary molars; localizes foreign bodies or pathology in posterior maxilla.
Vertical angulation: Central ray directed at entering approximately above the eyebrows through the cheek, lateral to the bridge of the nose.


Maxillary Pediatric Projection:
Clinical application: Investigates maxillary anterior dentition and development in children aged or younger.
Receptor type: Size 2 intraoral film/phosphor plate/sensor.
Vertical angulation: Central ray directed at through the bridge of the nose.


Mandibular Projections:
Mandibular Topographic Projection:
Clinical application: Evaluates mandibular anterior teeth and the surrounding alveolar bone.
Vertical angulation: Central ray directed at through the center of the chin.


Mandibular Cross-Sectional Projection:
Clinical application: Visualizes buccal and lingual cortical plates of the mandible; localizes radiopaque salivary calculi (sialoliths) or foreign objects in the floor of the mouth.
Vertical angulation: Central ray directed at to the receptor, centered approximately below the chin.


Mandibular Pediatric Projection:
Clinical application: Investigates anterior mandibular anatomy in children aged or younger.
Receptor type: Size 2 intraoral receptor.
Vertical angulation: Central ray directed at entering directly through the center of the chin.


Summary of Standard Occlusal Vertical Angulations:
Maxillary Topographic:
Maxillary Lateral (Right or Left):
Maxillary Pediatric:
Mandibular Topographic:
Mandibular Cross-Sectional: (perpendicular to receptor)
Mandibular Pediatric:
Localization Techniques: Fundamentals and Clinical Indications
Diagnostic Rationale:
A conventional intraoral dental radiograph is a two-dimensional () representation of a three-dimensional () structure.
Standard images provide superior-inferior and anterior-posterior detail but fail to depict buccolingual relationship or true anatomical depth.
Localization techniques provide the necessary third dimension of depth to pinpoint anatomical or foreign bodies.
Indications:
Foreign bodies
Impacted teeth
Unerupted teeth
Retained roots
Root canal curvatures and root positions (e.g., separating buccal vs. lingual roots)
Sialoliths in salivary ducts
Broken needles, endodontic files, or surgical instruments
Osseous jaw fractures
Overextended dental restorative materials (amalgam, cements) or implant components
Impact of Cone-Beam Computed Tomography (CBCT):
CBCT allows direct three-dimensional viewing of maxillofacial anatomy, supplanting traditional two-dimensional localization.
In dental practices lacking CBCT technology, conventional 2D radiographic localization rules remain clinically mandatory.
The Buccal Object Rule and the SLOB Concept
Principles of the Buccal Object Rule:
Governs the orientation of structures depicted on two radiographic images exposed at different beam angulations.
Procedural Steps:
Expose one periapical or bitewing receptor using standard technique, proper alignment, and angulation.
Expose a second periapical or bitewing receptor after deliberately altering the angulation of the x-ray beam (either shifting horizontal or vertical angulation).
Process both radiographs and visually compare the relative spatial displacement of the object against surrounding anatomical landmarks.
The SLOB Rule Mnemonic:
S = Same
L = Lingual
O = Opposite
B = Buccal
Rule Definition:
When an object seen in the second image appears to have moved in the Same direction as the horizontal/vertical shift of the PID tubehead, the object is located on the Lingual.
When an object seen in the second image appears to have moved in the Opposite direction of the horizontal/vertical shift of the PID tubehead, the object is located on the Buccal.


Directional Dynamics:
If the tubehead moves mesially, an object on the lingual aspect shifts mesially on the radiograph (Same = Lingual).
If the tubehead moves mesially, an object on the buccal aspect shifts distally on the radiograph (Opposite = Buccal).
If the tubehead vertical angulation increases (, PID points further downward), a lingual object shifts downward (Same), while a buccal object shifts upward (Opposite).
The Right-Angle Technique for Three-Dimensional Localization
The right-angle technique represents an alternative method to determine the three-dimensional spatial orientation of an object, primarily utilized in the mandible.
Procedural Steps:
Expose a periapical receptor using proper technique and standard angulation to record the object in coronal-apical and mesial-distal planes.
Expose an occlusal receptor on the same arch, directing the central ray perpendicular () directly to the receptor (cross-sectional projection).
Compare the periapical and cross-sectional occlusal radiographs side by side.
The cross-sectional occlusal image provides the critical right-angle view ( to the periapical plane), visually revealing whether the object lies toward the buccal or lingual cortex and defining its depth in the floor of the mouth or mandibular basal bone.

Clinical Application Example:
A radiopaque metallic foreign object visualized in the mandibular premolar region on a periapical radiograph can be definitively localized on the accompanying cross-sectional occlusal radiograph, confirming whether surgical access must occur from the buccal vestibule or lingual floor of the mouth.


Questions & Discussion
Why is the receptor bite-block of the Rinn BAI system angled rather than parallel with the aiming ring?
In bisecting technique, the receptor rests against the crowns and palatal/lingual tissues at an angle rather than parallel to the tooth's long axis.
The bite block is preset at a fixed angle to align the aiming ring perpendicular to the imaginary bisector, rather than perpendicular to the receptor or tooth.
Why does incorrect horizontal angulation cause overlapping?
When the central ray is directed diagonally rather than parallel through the contacts, the proximal surface of one tooth is superimposed over the proximal surface of the adjacent tooth.
Why are anterior periapical exposures executed prior to posterior periapical exposures?
Anterior placements utilize smaller, narrower receptor footprints that are easier for the patient to tolerate.
Starting in the anterior region acclimates the patient to intraoral hardware without triggering the gag reflex, which is far more sensitive in the posterior molars and soft palate.
Why must patients be reclined for mandibular occlusal radiographs?
To obtain a mandibular cross-sectional projection, the central ray must enter at to the receptor from beneath the chin.
Reclining the patient backward elevates the mandible and aligns the occlusal plane perpendicular to the floor, providing necessary physical clearance for the bulky tubehead to fit beneath the submental space.
What receptor size is used for pediatric occlusal exposures?
A size 2 intraoral receptor is used for children aged or younger, positioned horizontally between the arches.
Are specialized sterilization packages opened before or during patient positioning?
Instruments must remain sealed until the patient is seated, draped, and prepared; packages are opened immediately before use in front of the patient to maintain aseptic chains and prevent airborne contamination.
Clinical SLOB Case: Localization of an Amalgam Pit Restoration:
Question: On a reference molar bitewing, a radiopaque amalgam restoration is centered on the crown. When the PID is angled distally, the amalgam spot moves mesially on the second image. Is the restoration on the buccal or lingual surface?
Analysis: The PID shifted distally, and the object moved mesially (Opposite direction). Applying the SLOB rule: Opposite = Buccal. The amalgam restoration is in the buccal pit.
Clinical SLOB Case: Localization of an Impacted Canine:
Question: A maxillary periapical shows an unerupted canine superimposed on the lateral incisor root. A second periapical is taken with the tubehead shifted mesially; the crown of the unerupted canine shifts mesially over the central incisor. Is the canine located buccally or lingually?
Analysis: The PID shifted mesially, and the impacted canine moved mesially (Same direction). Applying the SLOB rule: Same = Lingual. The impacted canine is situated palatally/lingually.
Clinical SLOB Case: Multi-Rooted Premolar Root Separation:
Question: A maxillary first premolar has two root canals (buccal and lingual) superimposed on a straight-on image. When the tubehead is shifted mesially, one root canal appears to move toward the distal. Which root is this?
Analysis: The tubehead shifted mesially, and the root moved distally (Opposite direction). Opposite = Buccal. This root is the buccal root.